Skip to content

How Is Clamping Force (Tonnage) Calculated?

How Is Clamping Force (Tonnage) Calculated?

We explain step by step, with a numerical example, how to find the clamping force required for an injection molding machine as a preliminary calculation, using projected area, cavity pressure and a safety margin. This calculation is for preliminary assessment; a technical consultation is required for the final selection.

The tonnage of an injection molding machine, that is, its clamping force, is the first and most fundamental criterion in selection. When the mold is closed, molten plastic fills the cavity at high pressure and tries to open the mold; the machine must keep the mold closed against this force. If the force is insufficient, flash forms on the edges of the part; if it is excessively large, an unnecessary investment has been made. The method below provides a preliminary assessment; for a final selection, mold and material details and a technical consultation are required.

Basic formula

The required clamping force is found by adding a safety margin to the force that the pressure inside the mold exerts on the projected area of the part:

  • F (kN) = A (cm²) × p (bar) × 0.01
  • F (ton-force) = F (kN) ÷ 9.81
  • Required force = F × (1 + safety margin)

Here A is the total projected area of the cavities and cold runner channels when viewed from the mold closing direction; p is the average pressure inside the mold (this is not the same as the injection pressure).

Step-by-step calculation

  1. Find the projected area of a single part in the closing direction (the area of the face that faces the part as the mold closes).
  2. Multiply by the number of cavities; if a cold runner is used, add the projected area of the runner channels.
  3. Select an average cavity pressure according to the material and the part structure.
  4. Calculate the force with the formula and add a safety margin such as 10-20%.
  5. Consider the first suitable machine class above the value you obtain.

Example calculation

Example calculation for a 4-cavity mold
StepValue
Projected area of a single part90 cm²
Number of cavities4
Total cavity area90 × 4 = 360 cm²
Cold runner projected area40 cm²
Total projected area (A)360 + 40 = 400 cm²
Average cavity pressure (p)350 bar
Clamping force (F)400 × 350 × 0.01 = 1,400 kN (approx. 143 tons)
Required force with a 15% safety margin1,400 × 1.15 = 1,610 kN (approx. 164 tons)

In this example, the first machine class with a clamping force of 1,610 kN or more that also fits your mold dimensions is considered.

Approximate values for cavity pressure

Approximate values, as general guidance
Part typeApproximate average pressure
Easy-flow materials, medium and thick-walled parts (e.g. PE, PP)250-350 bar
General-purpose engineering plastics (e.g. ABS, PA)300-450 bar
Thin-walled parts or parts with long flow paths450-700 bar and above

These ranges are only a rough starting point. The actual pressure varies according to the flowability of the material, the mold and melt temperature, the wall thickness, the flow length and the injection speed. If possible, mold flow analysis and the recommendations of the mold maker or the raw material supplier should be taken as the basis.

Other points that affect the calculation

  • Hot runner: In hot runner systems, the runner area is generally not added to the projected area; however, it should be assessed according to the mold design.
  • Side actions and cams: Angled or side-action mechanisms can generate additional force.
  • Mold dimensions: Even if the tonnage is sufficient, the mold must fit within the tie bar spacing and the platen dimensions.
  • Shot weight: In addition to clamping force, sufficient shot capacity is needed for the weight of the part and runner.
  • Units: 1 ton-force is approximately 9.81 kN; since listings may use tons, kN or tf, compare the units carefully.

Reverse calculation: what area does the existing machine cover?

Starting from the clamping force of the machine you have, you can also find the largest projected area you can work with: A (cm²) = F (kN) ÷ (p × 0.01). For example, if you work at an average pressure of 350 bar on a machine with a clamping force of 1,800 kN, the limit area is 1,800 ÷ 3.5 ≈ 514 cm². If you want to leave a 15% safety margin, dividing this value by 1.15 gives approximately 447 cm². If you are designing a new mold, the total projected area needs to be kept below this limit.

Common mistakes

  • Confusing injection pressure (hydraulic or specific injection pressure) with cavity pressure
  • Forgetting the cold runner area
  • Leaving no safety margin at all, or always keeping it very high
  • Looking at the clamping force and not checking whether the mold fits on the platens
  • Taking the pressure too low for thin-walled parts with long flow paths

Conclusion

A calculation based on projected area and pressure is a practical way to quickly narrow down the machine class. Even so, for a final tonnage and series selection, your mold dimensions, your material and your target cycle time need to be assessed together. Share your part and mold information with us and let's carry out the preliminary assessment together. For other selection criteria, you can see the 8-criteria guide.